Troubleshooting Copper Non-Cyanide
วิธีการแก้ไขน้ำยาชุบทองแดงไม่ใช้ไซยาไนด์เบื้องต้น
Troubleshooting Non-Cyanide Copper Plating Solutions
1. Slow or Poor Adhesion
1.1 Poor Surface Preparation
Check and improve the surface preparation of the workpieces.
1.2 Excess Copper in the Solution
Dilute the solution or reduce the amount of additive.
1.3 Low pH
Adjust the pH using Copper C.
2. Burnt Plating at High Current
2.1 Insufficient Copper B
Increase the amount of Copper B.
2.2 Low Temperature
Heat the solution to 55°C.
2.3 Excessive Current
Reduce the current.
2.4 Poor Agitation
Increase agitation or air flow.
2.5 Heavy Metal Contamination
Perform a dummy run using high current.
2.6 Low Copper Content
Add more copper or copper sulfate.
2.7 Excessive Impurities
Add 10% hydrogen peroxide as tested with Hull Cell.
2.8 pH Above 10.5
Reduce the pH.
3. Solution Turns Green
3.1 Insufficient Copper B
Increase the amount of Copper B.
3.2 Poor Agitation
Increase agitation or air flow.
3.3 Low Temperature
Heat the solution to 55°C.
4. Incomplete or Darkened Plating
4.1 Oil or Heavy Metal Contamination
Add 3-5 ml/L hydrogen peroxide, agitate for a long time, heat to 70°C, or filter with 5-10 g/L carbon powder.
4.2 Insufficient Copper B
Increase the amount of Copper B.
4.3 Excess Copper in the Solution
Dilute the solution or reduce the amount of additive.
Mixing Instructions
Preparation: Clean the plating tank and fill it with 50% distilled water.
Dissolve Copper Sulfate: Stir until the solution is clear.
Add Copper 220 B: Stir continuously until fully mixed.
Add Copper 220 A: Add gradually and stir continuously until fully mixed.
Adjust pH: Use Copper 220 Activator to adjust pH to:
For Steel: pH 9–10
For Zinc and Aluminum: pH 8.5–9.5
Add Distilled Water: Fill the tank and stir continuously for 30 minutes.
Adjust Temperature: Set to the desired operating temperature.
Before plating, activate the surface with 2–5% Copper 220 Activator.
Solution Movement
Hanging Tanks: Use agitation or air bubbling.
Barrel Tanks: Use a barrel speed of 3 – 5 RPM.
Filtration
Continuous Filtration: Filter the solution continuously or at least 3–5 times per hour.
Filter Size: Use 5–10 micron filters.
Anode and Cathode Setup
Anodes: Use Oxygen Free High Conductivity (OFHC) copper plates with acid-resistant cloth bags.
Anode to Cathode Ratio: 2:1–3:1.
Solution Temperature: 50 – 60°C.
Copper Metal Levels
New Solution: 6 g/L.
Working Solution: 6 – 8 g/L.
Current and Plating Speed
Maximum Current: 2 A/dm².
Plating Speed: At 1 A/dm², plating rate is 0.17 microns/minute.
Solution Adjustment and Maintenance
Copper 220A: Use for new solution preparation.
For Copper Deficiency: Add Copper Sulfate 4 g/L and Copper 220B 16 cc/L.
Copper Sulfate Adjustment: 1 kg requires 4 L of Copper 220B.
For Gloss: Adjust Copper 220B as needed, with consumption of 0.8 - 1.0 L per 1,000 ampere-hours (AH).
pH: Regularly measure and adjust pH with Copper 220 Activator.
Post-Plating Cleaning and Maintenance
Rinse: Clean thoroughly with water at least 3 times.
Acid Dip: Dip in 5% sulfuric acid or 5% acid powder to neutralize alkalinity and prevent tarnishing.